(3) Removing the power supply board and high voltage board
1. Remove the process unit (See page 1-6-2).
2. Remove the left cover (See page 1-6-4).
3. Remove three connectors from the power supply board.
4. Remove eight screws.
5. Remove the power supply board and high voltage board. (Note: The high voltage board is directly connected to the
bias board.)
6. Separate the high voltage board from the power supply board.
Figure 1-6-14 Removing the power supply board and high voltage board
Screws
Screws
Connectors
Power supply
board
High voltage
board
Bias board