2DC
1-6-13
(4) Removing the bias board
1. Remove the cassette and process unit (See page 1-6-2).
2. Remove the left cover (See page 1-6-4).
3. Remove the power supply board and high voltage board (See the previous page).
4. Stand the machine with the front side up.
5. Remove one connector from the bias board.
6. Remove five screws.
7. Remove the bottom cover.
8. Remove the two connectors from the bias board.
9. Remove the bias board.
Figure 1-6-15 Removing the bias board
Connector
Connectors
Bottom cover
Bias board
Screws
Screws