2DF
1-5-10
4. Eject section
• Misfeed in eject section (jam code 50)
The eject switch (ESW) does not turn off within 2898 ms of the registration switch (RSW) turning off.
2898 ms
RSW
ESW
OFF
ON
OFF
ON
Timing chart 1-5-33
The eject switch (ESW) does not turn off within 2898 ms of the registration clutch (RCL) turning on.
2898 ms
RCL
ESW
OFF
ON
OFF
ON
Timing chart 1-5-34
• Misfeed in job separator* eject section (jam code 51)
The job separator eject switch (JBESW) does not turn on within 2050 ms of the feedshift switch (FSSW) turning on.
2050 ms
FSSW
JBESW
OFF
ON
OFF
ON
Timing chart 1-5-35
The job separator eject switch (JBESW) does not turn off within 2050 ms of the feedshift switch (FSSW) turning off.
2050 ms
FSSW
JBESW
OFF
ON
OFF
ON
Timing chart 1-5-36
The job separator eject switch (JBESW) does not turn off within 2050 ms of the feedshift switch (FSSW) turning on.
2050 ms
FSSW
JBESW
OFF
ON
OFF
ON
Timing chart 1-5-37
*Optional.