2JB/2JC
1-3-54
U344
Setting the low-power mode
Description
Changes the control for low-power mode.
Purpose
According to user request, selects which has priority, the recovery time from low-power or energy saver.
Setting
1. Press the start key.
2. Select control mode.
Initial setting: ENERGY STAR (120 V specifications)/GEEA (220-240 V specifications)
3. Press the start key. The setting is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U345
Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is about to be reached, by setting the
number of copies that can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the message is displayed.
This maintenance mode is effective for only Japanese specification.
Maintenance
item No.
Description
Display Description
ENERGY STAR The fuser control temperature is as low-power mode control tempera-
ture and forced stabilization is performed 30 seconds after exiting
preheat.
GEEA The fuser control temperature is as low-power mode control tempera-
ture and forced stabilization is performed 30 seconds after exiting
preheat.