3-2-72
2A3/4
Description
Maintenance
item No.
U252 Setting the destination
Description
Switches the operations and screens of machines according to the
respective destinations.
Purpose
To be executed after replacing the backup RAM on the main PCB or
initializing the backup RAM by running maintenance item U020, in order to
return the setting to the value before replacement or initialization.
Method
Press the print key. The screen for entering an item is displayed.
Setting
1 Select the destination. The selected item is displayed in reverse.
2 Press the print key. The value is set, and the screen for selecting a
maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/
clear key. The screen for entering a maintenance item No. is displayed.
Supplement
The specified initial settings are provided according to the destinations in
the maintenance items below. To change the initial settings in those items,
be sure to run maintenance item U021 after changing the destination.
• Initial setting according to the destinations
Display
JAPAN METRIC
INCH
EUROPE METRIC
ASIA PACIFIC
Description
Metric (Japan) specifications
Inch specifications
Metric (Europe) specifications
Metric (Asia Pacific) specifications
Maintenance
item No.
198
253
255
347
348
Title
Setting the fixing
phase control
Switching between
double and single counts
Setting auto clear time
Setting auto drawer
size detection
Setting copy density
adjustment range
Japan
ON
SINGLE
COUNT
120 s
ON
NORMAL
Inch
OFF
DOUBLE
COUNT
90 s
ON
SPECIAL
AREA
Europe Metric,
Asia Pacific
ON
DOUBLE
COUNT
90 s
OFF
SPECIAL
AREA