2A3/4
3-3-36
( 7 ) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is
not correct.
U065
U403
(P.3-3-40)
U 066
(P.3-3-39)
Caution: Check the copy image after the adjustment. If the image is still incorrect,
perform the above adjustments in maintenance mode.
<Procedure>
Enter maintenance mode.
Enter "065" using the numeric keys.
Yes
No
Start
End
Press the interrupt key.
Exit maintenance mode.
Set an A3 size original and
make a test copy with
the 100% magnification.
Is the image correct?
Setting range: –25 - +25
Reference: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
For copy example 1, increase the
value using the Up key.
For copy example 2, decrease
the value using the Down key.
Press the print key.
The new setting
is stored.
Select "MAIN SCAN ADJ"
(main scanning direction).
Press the print key.
Press the stop/clear key.
Original Copy
example
Copy
example 2
Figure 3-3-44