2A3/4
3-3-75
( 6 ) Replacing the heat roller separation claws
Replace the heat roller separation claws as follows.
<Procedure>
1. Open the fixing unit cover.
2. Remove the E-ring from the heat roller separation claw shaft and the springs from
the seven heat roller separation claws.
3. Remove the heat roller separation claws from the fixing unit upper guide.
4. Replace the heat roller separation claws.
Springs
Fixing unit upper guide
Heat roller separation claws
E-ring
Fixing unit cover
Figure 3-3-88 Detaching the heat roller separation claws
5. Refit all removed parts.