2A3/4
3-3-76
( 7 ) Detaching and refitting the press roller separation claws
Replace the press roller separation claws as follows.
<Procedure>
1. Open the fixing unit cover.
2. Remove the two E-rings from each of the press roller separation claws and then the
four claws.
3. Replace the press roller separation claws.
Fixing unit cover
Press roller separation claws
Figure 3-3-89 Detaching the press roller separation claws
4. Refit all removed parts.