2A3/4
3-5-12
Defective
power source
PCB.
Defective en-
gine PCB.
Defective laser
diode.
Defective poly-
gon motor.
Defective main
PCB.
Defective high-
voltage trans-
former PCB.
Leakage during
main charging.
Defective high-
voltage trans-
former PCB.
Leakage during
transfer/sepa-
ration charging.
Poor contact of
the fixing unit
thermistor con-
nector termi-
nals.
Broken fixing
unit thermistor
wire.
Fixing unit ther-
mistor installed
incorrectly.
Fixing unit ther-
mostat
triggered.
Check if 24 V DC is supplied
to CN6-5 on the engine PCB.
If not, replace the power
source PCB.
Check if 24 V DC is output
from CN7-1 on the engine
PCB. If not, replace the engine
PCB.
Replace the LSU.
Replace the LSU.
Replace the main PCB.
Replace the high-voltage
transformer PCB.
Check and clean the main
charger assembly.
Replace the high-voltage
transformer PCB.
Check and clean the transfer
charger assembly.
Check the connection of con-
nector CN3-B8 on the engine
PCB and the continuity across
the connector terminals. Re-
pair or replace if necessary.
Measure the resistance. If it is
infinite, replace the fixing unit
thermistor.
Check and reinstall if neces-
sary.
Check for continuity. If none,
replace the fixing unit thermo-
stat.
C401
C420
C510
C511
C610
Polygon motor steady-
state problem
The polygon motor rotation
is not stable for 600 ms af-
ter the polygon motor rota-
tion has been stabilized.
BD steady-state problem
The VTC detects a BD er-
ror for 600 ms after the
polygon motor rotation has
been stabilized.
Main charger problem
MC ALM signal is detected
continuously for 400 ms
when MC REM signal is
turned on.
Transfer/separation high-
voltage problem
STALM signal is detected
continuously for 400 ms
when TC/SC REM signal is
turned on.
Broken fixing unit ther-
mistor wire
The fixing temperature
does not increase for 40 s
after the fixing heaters
have been turned on for
warming up.
The fixing temperature re-
mains below 50˚C/122˚F
for 10 s continuously after
the fixing heaters have
been turned on during sta-
bilization.
Code Contents
Remarks
Causes
Check procedures/
corrective measures