1-5-37
8. Wind the outer scanner wires around the outside grooves in the pulleys of the mirror frame 2 from above
to below. ................................................................................................................................................(1)
9. Hook the round terminals to the catches inside the scanner unit. .........................................................(2)
10. Wind the inner scanner wires around the grooves in the pulleys at the left of the scanner unit from below
to above. ................................................................................................................................................(3)
11. Wind the scanner wires around the inside grooves in the pulleys of the mirror frame 2 from below to
above. ....................................................................................................................................................(4)
12. Wind the scanner wires around the grooves in the pulleys at the left of the scanner unit......................(5)
13. Hook the round terminals to the scanner wire springs. ..........................................................................(6)
Figure 1-5-65
14. Remove the two scanner wire stoppers
and the two frame securing tools.
15. Move to center the portion of the locat-
ing ball in the scanner wire drum, and
the scanner wires to inside.
16. Move the mirror frame 2 from side to
side in order to correctly locate the
wires in position.
17. Refit the mirror frame 1.
18. Move the mirror frame 1 and 2 to the left
side of the machine, and insert the two
frame securing tools into the positioning
holes at the front and rear of the scan-
ner unit to secure the frames in posi-
tion.
19. Hold the wires and fix each front and
rear wire holder plate to the mirror
frame 1 with the screw.
20. Remove the two frame securing tools.
21. Refit all the removed parts.
Figure 1-5-66
Black marking
Gray Black
Frame securing tool
Frame securing tool
Mirror frame 2
Mirror frame 1