(2-5) U010XX error code table: G3 transmission
Error code Description
U01000/E01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001/E01001 Function of the unit differs from that indicated by a DIS signal.
U01016/E01016 An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01019/E01019 No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020/E01020 No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021/E01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022/E01022 No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01028/E01028 T5 time-out was detected during ECM transmission (ECM).
U01052/E01052 A DCN signal was received after transmission of an RR signal (ECM).
U01080/E01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01092/E01092 During transmission in V.34 mode, communication was interrupted because of an impos-
sible combination of the symbol speed and communication speed.
U01093/E01093 A DCN or other inappropriate signal was received during phase B of transmission.
U01094/E01094 The preset number of command retransfers for DCS/NSS signals was exceeded during
phase B of transmission.
U01095/E01095 No relevant signal was received after transmission of a PPS (Q) signal during phase D of
transmission, and the preset number of command transfers was exceeded.
U01096/E01096 A DCN signal or invalid command was received during phase D of transmission.
U01097/E01097 The preset number of command retransfers was exceeded after transmission of an RR
signal or no response.