2L6/2N6/2N5/2N4
1-4-94
2600 PF paper feed motor error
(large capacity feeder)
After PF paper feed motor is
driven, the ready signal does
not turn to L within 2 s.
PF paper feed
motor
1. To check the feed unit operation, exe-
cute U247 LCF- Motor ON (see page 1-
3-148).
2. Check the paper feed roller and drive
gear can rotate or they are not unusually
loaded and, if necessary, replace.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
PF paper feed motor and PF main PWB
(YC16)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the paper feed motor.
PF main PWB
Replace the PF main PWB (Refer to the
service manual for the paper feeder).
2610 PF paper feed motor error
(paper feeder)
[45 ppm/55 ppm model]
After PF paper feed motor is
driven, the ready signal does
not turn to L within 2 s.
PF paper feed
motor
1. To check the feed unit operation, exe-
cute U247 2PF - Motor ON (see page 1-
3-148).
2. Check the paper feed roller and drive
gear can rotate or they are not unusually
loaded and, if necessary, replace.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
PF paper feed motor and PF main PWB
(YC16)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the paper feed motor.
PF main PWB
Replace the PF main PWB (Refer to the
service manual for the paper feeder).
Code Contents Related parts
Check procedures/