2KN/2KP
2-3-59
YC7 1 5V O 5 V DC 5 V DC power output
Connected
to the origi-
nal feed
switch, origi-
nal registra-
tion switch,
DP timing
switch 1 and
2
2 FDSW I 0/5 V DC Original feed switch: On/off
3 SGND - - Signal ground
4 5V O 5 V DC 5 V DC power output
5 REGSW I 0/5 V DC Original registration switch: On/off
6 SGND - - Signal ground
7 5V O 5 V DC 5 V DC power output
8 TMG1SW I 0/5 V DC DP timing switch 1: On/off
9 SGND - - Signal ground
10 5V O 5 V DC 5 V DC power output
11 TMG2SW I 0/5 V DC DP timing switch 2: On/off
12 SGND - - Signal ground
YC8 1 LED O 0/5 V DC (pulse) Original length size switch LED
Connected
to the origi-
nal length
size switch
and original
width size
switch
2 SGND - - Signal ground
3 ORIG.LSW I 0/5 V DC Original length size switch: On/off
4 5V O 5 V DC 5 V DC power output
5 5V O 5 V DC 5 V DC power output
6 ORGW I 0/5 V DC Original width size switch: On/off
YC10 1 24V O 24 V DC 24 V DC power output
Connected
to DP safety
switch 1 and
2
2 N.C - - Not used
3 24V DPOPNSW I 0/24 V DC DP safety switch 1: On/off
4 24V O 24 V DC 24 V DC power output
5 N.C - - Not used
624V COVOP-
NSW
I 0/24 V DC DP safety switch 2: On/off
YC12 1 24V O 24 V DC 24 V DC power output
Connected
to the DP
inverter
PWB
2 INV REM O 0/24 V DC CIS control signal
3 PGND - - Power ground
YC13 1 5V O 5 V DC 5 V DC power output
Connected
to the CIS
open/close
switch
2 CISOPNSW O 0/5 V DC CIS open/close switch: On/off
3 SGND - - Signal ground
YC15 1 24V O 24 V DC 24 V DC power output
Connected
to the DP
fan motor 1
and 2
2 CISFANREM O 0/24 V DC DP fan motor 1: On/off
3 MOTFANREM O 0/24 V DC DP fan motor 2: On/off
4 24V O 24 V DC 24 V DC power output
Connector Pin No. Signal I/O Voltage Description

Table of Contents