5-12
Corrective action when service call occur > C2100
[CONFIDENTIAL]
7
Remove the left plate.
In case of (1), go to step 11.
8
Rotate the lift motor [A] of the image conveying unit by hand, and wind up the image
conveying unit lifting wire [B].
Stretch and put tension on the wire slightly when wind it up.
Wind up the wire until the image conveying belt get around removal position (fix bracket position).
9
Check if the shaft [B] is inserted in the lift guide [A].
[B]
[A]
[B]
[B]
[A]
[B]