3-43
Maintenance > Parts Replacement
18
Move the lever for retard pressure to the original position.
19
Attach the cassette feed unit to cassette 1.
20
Return the Cassette 1 to its original position, and close Front
Covers 2 and 4.
21
[Home] key > [...] > [Professional Settings] > [U251 Clear
Maintenance Counter].
22
Select [01 Cassette 1] or [02 Cassette 2] > [Start] key.
The counter for replaced part is cleared.
Check the status after replacement
Make a test print and check that there are no paper jams, double feed or no feed. If there is any problem, try again from
step 1.
If the problem is not resolved, contact your service representative.
Make sure that attached shaft is on the position shown below.