Amplifier Technology | Class D |
---|---|
Number of Channels | 8 |
Input Type | Analog, AES/EBU |
Weight | 13.9 kg |
DSP | Yes |
Connectors (Inputs) | XLR, AES/EBU |
Input Connectors | XLR, AES/EBU |
Frequency Response | 20 Hz - 20 kHz |
Signal to Noise Ratio | > 100 dB |
THD+N | < 0.1% |
Total Harmonic Distortion | < 0.1% |
Operating Voltage | 100-240 V AC |
Dimensions (H x W x D) | 3.5 x 19 x 15.7 in |
Connectors (Outputs) | Speakon NL4 |
Output Connectors | Speakon NL4 |
Cooling | Forced air |
General guidelines and warnings for safe operation and installation of the LA8 amplified controller.
Explanation of warning symbols used in the manual for hazard identification and compliance.
References for user manuals of loudspeaker systems and their connection to controllers.
Components like LA8, LA-RAK, and L-CASE for system power, control, and transport.
References for detailed instructions on loudspeaker system cabling.
Information on LA Network Manager software for remote control and monitoring.
Overview of the LA8's core DSP, memory, converters, power supply, and interfaces.
Detailed identification and description of all connectors, controls, and indicators on the unit.
Explanation of analog and AES/EBU digital audio inputs and their signal processing.
How proprietary algorithms and filters ensure performance and transducer protection.
Details on Class D technology, auto-sensing SMPS, and output power capabilities.
Information on the front panel user interface and L-NET remote control network.
Instructions for rack-mounting the LA8 unit, including dimensions and transport support.
Guidelines for maintaining optimal operating temperatures through proper airflow and grill clearance.
Electrical specifications, voltage requirements, power data, and circuit breaker advice.
Considerations for powering the LA8 from a generator, including kVA calculation.
Information on power cord types, plugs, and wiring color codes for safe connection.
Method to calculate heat power produced by the LA8 based on consumption and output.
Details on connecting speakers, audio sources, and network via rear panels.
Wiring details for speakON and CA-COM connectors for loudspeaker outputs.
Diagrams illustrating the signal flow from DSP to loudspeaker output connectors.
Description of XLR connectors for analog and digital audio signal cabling.
Information on network setup, cable specifications, and connection topology for remote control.
Guidelines on connecting enclosures using speakON or CA-COM connectors, including compatibility.
Step-by-step instructions for turning on the amplified controller and its start-up sequence.
Procedure for shutting down the amplified controller and its shutdown sequence.
How to put the controller into standby mode to reduce electrical consumption.
Explanation of the L-NET LED status indicator on the front panel.
Description of LED meters for output channel status like CLIP, SIGNAL, and LOAD.
Explanation of the elements displayed on the main screen after controller startup.
Overview of immediate functions available directly from the main screen.
Procedure to lock or unlock the front panel controls to prevent accidental changes.
How to mute or unmute individual output channels using the front panel OUT keys.
Steps to adjust the gain for output channels or channel sets using the encoder wheel.
Method to identify a controller on the L-NET network via the front panel or LA Network Manager.
How to view signal levels, input assignments, and group status on the controller.
Navigation through the main menu for accessing functions and submenus.
Procedure for loading user or factory presets from the controller's memory.
How to save the current controller settings as a user preset.
Procedure to delete a user preset from the controller's memory.
Setting individual parameters like gain, delay, polarity, and input selection for presets.
Removing group parameters assigned via LA Network Manager from the controller.
Configuring input mode, fallback mode, and AES/EBU gain settings.
Avoiding sound cuts by enabling automatic switching to analog input on digital failure.
Adjusting gain for AES/EBU input to align levels for seamless fallback switching.
Viewing real-time measurements, firmware, and controller information.
Accessing general settings like IP address, delay unit, and screen contrast.
Setting the IP address for the controller's network communication.
Selecting the unit for displaying delay values (ms, meters, feet, samples).
Adjusting the LCD screen contrast for optimal visibility in different environments.
Restoring all controller settings to their factory default values.
Enabling and bypassing protection for settings using a 4-digit PIN code.
Information on system messages and their corresponding events in LA Network Manager.
Handling of under/over-voltage and SMPS status messages related to power supply.
Monitoring and resolution of external errors detected at output channels.
Monitoring and resolution of internal errors detected at output channels.
Handling of invalid L-NET client connection attempts due to version incompatibility.
Explanation of firmware update errors and temperature-related messages.
Typical values for output power, voltage, DSP, frequency response, and noise level.
Power consumption and current draw data for various operating conditions.
Voltage and frequency ratings for different LA8 models (LA8, LA8US, LA8JP).
Recommended room temperature and internal controller temperature limits.
Details on circuits, transducers, and fan protection mechanisms used in the LA8.
Information on indicators, LCD screen, output connectors, and L-NET ports.
Specifications for input and link connectors, including analog, digital, and USB.
Input impedance, maximum input level, and A/D conversion details for analog signals.
Supported modes, sampling frequencies, word lengths, and SRC specifications for digital signals.
Latency values for analog and AES/EBU inputs in standard and low latency modes.
Dimensions, weight, and finish specifications of the LA8 unit.
Declaration of Conformity and applied safety and EMC standards for the LA8.