HOME FIRE SAFETY
Installation and use of the stove should be in accordance with the instructions of the
manufacturer and the local rules of habitability.
• When a flue pipe pass through a wall or ceiling particular methods of installation
should be applied (protection, thermal insulation, distance from heat sensitive
material, etc)
• Never connect the stove to a chimney already used for another device.
• Keep away from the fireplace radiation area all combustible and flammable materials
(wood furniture, curtains, flammable liquids, etc…)
• If nearby there are shells in combustible or sensitive to heat material, an insulating
and not combustible protection must be interponed.
• If the floor is made in combustible material, at the mouth of the fireplace a protection
made of incombustible material should be placed – with a lateral extension of 20 cm
and a frontal extension of 60 cm.
• For further information please refer to the rule UNI 10683.