8
7. Technical specification
8. Maintenance
This instrument could not be sunk in the water and could not be wet with rain.
This instrument should be carefully operated and properly preserved, any violent shock or falling possibly result in
the damage of instrument.
Before moving or shipping the instrument, please set the instrument in locking status to avoid influencing the
accuracy.
Do not attempt to disassemble the instrument, and any unprofessional disassembly will result in the damage of
instrument.
Keep the instrument clean, especially the laser output window glass, and remove dust by the gentle operation of
soft clean cloth.
Take the batteries out when the instrument is not is use for a long time, and keep the instrument in the carrying
case when it is not in use.
=
Item Parameter
Laser wavelength 635nm
Laser class Class
Accuracy ±1mm/5m(1° vial range)
Self-leveling range ±3°
Temperature range
-10+45Red
0+40Green
Power supply
3*AA batteries or Li battery box or
adapter
Low voltage indicate
Power indication light flash
Size φ100×216mm
Weight 1.15Kg