LASER TOOLS Cam Belt Tensioner Gauge
9
DISPLAY CONTRAST
RESTORE DEFAULTS
TURN BEEPER ON [OFF]
TURN LEDS ON [OFF]
Press the key to select the required option.
This performs the menu operation and returns to the menu
header screen, except for the calibration procedure, which
had several steps. To exit the menus without making a
selection, press the ‘Menu’ key again.
This allows the user to access the display contrast setting if it
requires adjustment at any time other than at switch-on. The
procedure for adjustment is the same as at switch-on.
This restores the following default settings:
Contrast
Units
Tension high limit
Tension low limit
50%
Newtons
250
200
When ‘TURN BEEPER ON’ is displayed, pressing the key
turns the beeper on for out of-limit indication.
When ‘TURN BEEPER OFF’ is displayed, pressing the key
turns the beeper off.
Note: The beeper always sounds to confirm a key press
or a fault condition.
When ‘TURN LEDS ON’ is displayed, pressing the key
turns the LED’s on for out-of limit indication. When ‘TURN
LEDS OFF’ is displayed, pressing the key turns the
LED’s off.
Note: The LED’s always light for a fault condition.
Calibration should be carried out after every 250 operations of
the unit, or at 6 month intervals.
After 220 operations the message ‘CAL. DUE: 30’ will be
displayed whenever the instrument is switched on. This
indicates that calibration will be due after the unit has been
switched on 30 more times. This figure will decrease every
time the unit is switched on. After 250 operations, the
message ‘CAL. OVERDUE: 01’ will be displayed whenever
the instrument is switched on.
CALIBRATION
DISPLAY CONTRAST
RESTORE DEFAULTS
TURN BEEPER ON [OFF]
TURN LEDS ON [OFF]
>
>
>
>
>