The last measurement value will continue to display for about
5 seconds after removing the device from the measured material.
The symbol of the selected mode ashes and the measured
value last determined is displayed. The device is ready for a new
measurement as soon as the ashing stops and the measured
value is reset to 0.
Auto-Hold function
Unit of temperature selection °C / °F
(see g. C, page 02)
Be aware that walls (or surfaces)
with differing material structures,
or even variations in material
composition, can cause measure-
ment results to be falsied. Perform
multiple comparative measurements.
You read off the measurement
results from the following index
scale and convert them to %
with the aid of the table.
Example
Building material: anhydrite screed
Measured value: 265
Result: 0.1% material moisture
The universal index mode is used to compare measuring points
and therefore to ascertain moisture. The moisture content of
building materials can be additionally determined in % with the
aid of the conversion table.
Index mode (Determine building moisture)
If there is no response when measuring,it is possible
that the measured material is too dry. Perform a self-test
of the device with the protective cap to make sure the
device is in good working order.
!