Technical data
Electronic measuring precision
± 0,1° at 0° … 1°
± 0,1° at 89° … 90°
± 0,2° at 1° … 89°
Display accuracy
1 decimal place
Vial
± 1 mm/m
Operating conditions
0 ... 50°C, 80%rH, no condensation,
max. working altitude 2000 m above sea level
Storage conditions
-20 ... 70°C, 80%rH, no condensation
Auto power off
after 3 minutes
Power supply 2 x 1.5V LR03 (AAA)
Dimensions (W x H x D) 25 240 x 66 x 30 mm
Dimensions (W x H x D) 40
400 x 66 x 30 mm
Dimensions (W x H x D) 60
600 x 66 x 30 mm
Weight 25
315 g (incl. batteries)
Weight 40 495 g (incl. batteries)
Weight 60 675 g (incl. batteries)
Subject to technical change without notice. Rev21W32
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must
be collected separately for disposal according
to the European Directive on waste electrical
and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=diglevpl
Backlighting
The backlighting is switched ON/OFF by pressing and holding button (6).
9
Auto Off function
In order to preserve the batteries, the measuring device switches off automatically if it is
left idle for 3 minutes.
EN
Danger – powerful magnetic fields
Powerful magnetic elds can adversely affect persons with active medical implants
(e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical
clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic elds on persons, the applicable national
stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic
elds“ (occupational health and safety - electromagnetic elds) in the Federal Republic
of Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at
least 30cm away from the magnet.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents
and solvents. Remove the battery(ies) before storing for longer periods. Store the device in
a clean and dry place.
Calibration
The meter needs to be calibrated on a regular basis to ensure it produces accurate measurement
results. We recommend carrying out calibration once a year. Contact your distributor or the
UMAREX-LASERLINER service department.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LaserLiner DigiLevel Plus 25 and is the answer not in the manual?

LaserLiner DigiLevel Plus 25 Specifications

General IconGeneral
BrandLaserLiner
ModelDigiLevel Plus 25
CategoryLaser Level
LanguageEnglish

Related product manuals