16
OCPP
TABLE OF CONTENTS
Configurations possibilities :
CORE PROFILE OCPP 1.6 READ WRITE BY DEFAULT REMARKS
AllowOfflineTxForUnknownId Optional OK Accepted False
AuthorizationCacheEnabled Optional OK Accepted False
AuthorizeRemoteTxRequests Required OK Accepted True
BlinkRepeat Optional OK Accepted 60
No action on Legrand station
ClockAlignedDataInterval Required OK Accepted 0
No action on Legrand station
ConnectionTimeOut Required OK Accepted 60
60sec by default
GetConfigurationMaxKeys Required OK N.A. 255
HeartbeatInterval Required OK Accepted 60
Between 10 and 86400 sec
LightIntensity Optional OK Rejected 100
No action on Legrand station
LocalAuthorizeOffline Required OK Accepted False
LocalPreAuthorize Required OK Accepted False
MaxEnergyOnInvalidId Optional OK Rejected 0
MeterValuesAlignedData Required OK Accepted
Please check “supportedMe-
terValuesAlignedData”
MeterValuesAlignedDataMa-
xLength
Required OK Rejected 50
MeterValuesSampledData Required OK Accepted
Please check “supportedMe-
terValuesSampledData”
MeterValuesSampledDataMa-
xLength
Optional OK Rejected 50
MeterValueSampleInterval Required OK Accepted 30
- 10 s
MinimumStatusDuration Optional OK Accepted 0
NumberOfConnectors Required OK N.A. 0
Depend of the reference of
the product
ResetRetries Required OK Accepted 1
ConnectorPhaseRotation Required OK Not supported Unknown
No action on Legrand station
ConnectorPhaseRotationMax-
Length
Optional OK N.A. 1
No action on Legrand station
StopTransactionOnEVSideDis-
connect
Required OK Accepted True
No action on Legrand station
StopTransactionOnInvalidId Required OK Accepted False