EasyManuals Logo

LEGRAND Bticino HD4607/4 User Manual

LEGRAND Bticino HD4607/4
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
1
4
2
6
5
7
3
1
02'
=
$8;
1
02'
=
$8;
1
02'
=
$8;
1
02'
=
$8;
HD4607/4
HC4607/4
N4607/4
L4607/4
NT4607/4
AM5787/4HS4607/4
Description
This device is used to arm, disarm, and separate the zones of the system by placing a
transponder badge (item 3530S and item 3540 previously stored in the central unit) in
front of the zone transponder badge receiver.
When used in an automation system it performs the control function for the management
of scenarios.
By pressing one of the pushbuttons, the corresponding zone is armed/disarmed.
Within four seconds from the last pressure, the separation performed must be conrmed
by moving a transponder saved in the central unit close to the device.
Should this not take place, then the previous condition is automatically restored. Red LEDs
on indicate that the zones are active, whereas red LEDs o show that they are disarmed.
Conguration
BURGLAR-ALARM mode:
Since this item belongs to the activator group, it needs to be set up with the number of
the group” assigned and the progressive number of the devices in the group. It can also
be programmed to perform Automation functions (scenario management).
See Automation “MY HOME” guide for details.
Z
This congurator assigns the number of the appropriate zone (from 1 to 8) in the group”
of devices (any free zone in the system). To congure it as belonging to the activator
group, no congurator must be inserted.
This congurator assigns the progressive number within the group of activators.
Congurator 1 identies the rst device, congurator 2 identies the second, and so
forth, up to a maximum of 9 activators (dividers, expanders or activators).
NOTE: If all 9 permitted devices have already been assigned to the activator group,
it could be possible to assign to congurator Z (zone it belongs to) a value between
1 and 9, taking into account the progressive number.
MOD
It assigns the modes of the audible signals (BEEP) and luminous signals (LED ON)
provided by the divider when controlled by the transponder; it is used as a activators/
disconnector of the “Burglar-alarm system.
Technical data
- Power supply from SCS BUS: 27 Vdc
- Max. absorption: 15 mA
- Operating temperature: 5 – 40°C
Legend
1 - Transponder badge receiver zone;
2 - LED and pushbutton for controlling of zone 2;
3 - LED and pushbutton for controlling of zone 4;
4 - Indication “System ON/OFF”;
5 - Alarm warning;
6 - LED and pushbutton for controlling of zone 3;
7 - LED and pushbutton for controlling of zone 1.
Dimensional data
Size: 2 modules
AUX
Position not congurable for the “Burglar-alarm” function; congure only if it is necessary
to enable the device for Automation functions (management of the scenarios stored in
the unit or scenario module).
Front view
Z
No.
MOD
AUX
Clamp for burglar
alarm BUS
Rear view
Central unit
used
Congurator
value
LED ON Enabling
BEEP
3486
3485/B
HD/HC/HS/L/N/
NT4601
none YES YES
1 NO YES
2 YES NO
3 NO NO
L/N/NT4600/1
A/AM5780/1
4 YES YES
5 NO YES
6 YES NO
7 NO NO
1-4 zone transponder
divider
MQ00028-c-EN 24/04/2014

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LEGRAND Bticino HD4607/4 and is the answer not in the manual?

LEGRAND Bticino HD4607/4 Specifications

General IconGeneral
BrandLEGRAND
ModelBticino HD4607/4
CategoryMarine Radio
LanguageEnglish