Model 6 kVA 10 kVA
Capacity 5.4kW 9 kW
BATTERY
Battery number 16/18/20 Pcs. Can be set
Battery type VRLA
Charge model Boost charge or float charge auto switch
Charge time Boost charge up to 20Hr (Max)
Charge current
(MAX.)
6A
AC OUTPUT
Output type Single phase & Ground
Voltage regulation ±1.0%
Voltage distortion
(THD)
less than 3% at 100% liner load
less than 5% at 100% non-liner load
Rated voltage 220V/230V/ 240Vac can be set
Frequency regula-
tion
±0.1% (stand alone)
Frequency
Utility mode, tracking mains frequency
Battery mode: 50Hz/60Hz
Frequency track
speed
1Hz/s
load capacity (Ma-
ins, drop a level in
battery mode)
105 % 110 %, lasts 10 minutes
110%130%, lasts 1minutes
130%,switch to bypass immediately
Overload for
bypass
95%, can not inverter-fed
Load for a long time when rated output current under
125%
Bypass load capacity is controlled by bypass circuit
breaker, tripping when circuit breaker operating
current.
Crest factor 3:1
Efficiency at AC ≥90%
Dynamic respond
± 5.0% (100% balance load)
≤5% in a cycle
Inverter output
current limit
When current instantaneous value is 2 ~ 3 times of
rated current peaks (1.414 * rated power/ (3 * 220)),
the inverter will be conducted in each pulse current
limit protection.
DC component ≤200mV