54
Thermostat with display
Installer manual
2.1 General features
The thermostat with display can be used both in heating and in air conditioning systems, and gives
the possibility of adjusting the temperature on 5 levels. Comfort, Eco, Antifreeze / Thermal Protec-
tion, Automatic, and Manual.
Based on the type of use, the backlit display will show the following information: the current func-
tion or mode (heating, cooling, or automatic function; Comfort, Eco, Antifreeze / Thermal Protec-
tion, Automatic, Temporary Manual, or Off ), the detected room temperature, the temperature set
point defined, the fan-coil speed, and the status of the zone.
The thermostat can be used in MyHOME temperature control systems (MyHOME probe with cen-
tral unit), hotel room systems, or residential systems (individual system). The configuration can be
done by connecting the configurators to the corresponding sockets in the back of the thermostat,
or using the MyHOME_Suite software.
Programming is simple and intuitive: to switch from one mode to the other press MODE,
+ or – .
Factory settings
Heating Cooling
Adjustment interval for hotel
or residential
14 – 26 °C 20 – 32 °C
Adjustment interval for
MyHOME
3 – 40 °C 3 – 40 °C
Comfort
21 °C 25 °C
Eco
18 °C 28 °C
Antifreeze
7 °C
Thermal protection
35 °C
2 Description