5.4008.8520.0 -
Specifications 3-3
Table 3. Specifications Water Filling Station
Water Filling Station
Dimensions and weight. Water filling unit:
• Width: 256 mm (10.08 in).
• Height: 472 mm (18.58 in).
• Depth: 489 mm (19.25 in).
• Weight: 9.68 kg (21.34 lb).
Water reservoir:
• Width: 645 mm (25.39 in).
• Height: 540 mm (21.26 in).
• Depth: 338 mm (13.31 in).
• Weight: 6.5 kg (14.33 lb); completely filled: 90 kg (198.41 lb).
Water Requirements.
• Min. water inlet pressure header tank: 1 bar (14.5 psi).
• Max. water inlet pressure header tank: 3 bar (43.5 psi).
• Min. required water flow for filling the header tank: 1.5 l/min (0.4 us
gal/min).
• Use potable water to prevent blockage of the nozzle or the water
pump.
Hygiene protection.
The header tank meets the standard ‘NEN-EN 1717:2000 en’ which
deals with the means to be used to prevent the pollution of potable
water inside premises and the general requirements of protection
devices to avoid pollution by backflow.
in n o vato rs in ag ric u ltu re