14ACX - 1.5 to 5 Ton Air Conditioner / Page 119
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43C EL296UH110XV48C 7783073
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL296UH110XV60C 7627979
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090V60C 7783074
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090XV60C 7627982
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110V60C 7783075
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110XV60C 7627985
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV36C 7783076
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV48C 7627988
14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43C SLP98UH090XV60C 7783077
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SLP98UH110XV60C 7627991
14ACXS042-230A TXV 41,000 14.25 12.00 CX34-43C 7627958
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090E48B 7627994
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090XE48B 7783079
14ACXS042-230A TXV 40,500 14.50 12.20 CX34-44/48B EL296UH045XV36B 7627997
14ACXS042-230A TXV 40,000 14.50 12.00 CX34-44/48B EL296UH070XV36B 7783080
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V36B 7628000
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V48B 7783081
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090XV48B 7628003
14ACXS042-230A TXV 40,000 14.50 12.00 CX34-44/48B SLP98UH070XV36B 7783082
14ACXS042-230A TXV 40,000 14.00 11.50 CX34-44/48B 7783078
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL180UH090E60C 7783083
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110E60C 7628009
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110XE60C 7783084
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL195UH090XE48C 7628012
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL195UH110XE60C 7628015
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XE48C 7783085
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C EL296UH090XV36C 7628018
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XV48C 7783087
14ACXS042-230A TXV 41,000 15.00 12.50 CX34-44/48C EL296UH090XV60C 7628021
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL296UH110XE60C 7783086
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV48C 7783088
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV60C 7628024
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090V60C 7783089
14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090XV60C 7628027
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110V60C 7783090
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110XV60C 7628030
14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SLP98UH090XV36C 7783091
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH090XV48C 7628033
14ACXS042-230A TXV 41,000 15.00 12.50 CX34-44/48C SLP98UH090XV60C 7783092
14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH110XV60C 7628036
14ACXS042-230A TXV 40,000 14.00 11.50 CX34-44/48C 7628006
14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH090E60C 7628039
14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110E60C 7783094
14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110XE60C 7628043
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL195UH090XE48C 7783095
14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL195UH110XE60C 7628046
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XE48C 7783096
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV36C 7628049
14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV48C 7783097
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.