14ACX - 1.5 to 5 Ton Air Conditioner / Page 125
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-018-230A RFC 19,000 14.00 12.20 C33-31A 7186906
14ACX-018-230A RFC 19,000 14.00 12.20 C33-31B 7186910
14ACX-018-230A RFC 18,000 14.00 12.20 C35-18/24A 8471005
14ACX-018-230A RFC 18,000 14.00 12.20 C35-18/24B 8471006
14ACX-018-230A RFC 19,200 14.25 12.20 CH33-31A 7186942
14ACX-018-230A RFC 19,100 14.25 12.20 CH33-31B 7186946
14ACX-018-230A RFC 19,000 14.00 12.20 CR33-30/36A 7186983
14ACX-018-230A RFC 19,000 14.00 12.20 CR33-30/36B 7186986
14ACX-018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045E36A 7186877
14ACX-018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045XE36A 7186876
14ACX-018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045E36A 7186880
14ACX-018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045XE36A 7186879
14ACX-018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045E36A 7186882
14ACX-018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045XE36A 7186881
14ACX-018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070E36B 7186884
14ACX-018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070XE36B 7186883
14ACX-018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH030XE24B 8608812
14ACX-018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH045XE24B 8608813
14ACX-018-230A TXV 18,600 14.50 12.50 C33-24B EL195UH045XE36B 7186885
14ACX-018-230A TXV 18,600 14.50 12.50 C33-24B EL296UH045XE36B 7186886
14ACX-018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045E36A 7186890
14ACX-018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045XE36A 7186889
14ACX-018-230A TXV 19,200 14.25 12.20 C33-25A 7186888
14ACX-018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070E36B 7186894
14ACX-018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070XE36B 7186893
14ACX-018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH030XE24B 8608814
14ACX-018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH045XE24B 8608815
14ACX-018-230A TXV 20,000 16.00 13.00 C33-25B EL195UH045XE36B 7186895
14ACX-018-230A TXV 20,000 16.00 13.00 C33-25B EL296UH045XE36B 7186896
14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH045XV36B 7186897
14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH070XV36B 7614659
14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B SLP98UH070XV36B 7523952
14ACX-018-230A TXV 19,200 14.25 12.20 C33-25B 7186892
14ACX-018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045E36A 7186899
14ACX-018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045XE36A 7186900
14ACX-018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070E36B 7186901
14ACX-018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070XE36B 7186902
14ACX-018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH030XE24B 8608816
14ACX-018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH045XE24B 8608817
14ACX-018-230A TXV 18,900 15.10 12.50 C33-30B EL195UH045XE36B 7186903
14ACX-018-230A TXV 18,900 15.10 12.50 C33-30B EL296UH045XE36B 7186904
14ACX-018-230A TXV 19,500 16.00 13.00 C33-30B EL296UH045XV36B 7186905
14ACX-018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045E36A 7186908
14ACX-018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045XE36A 7186909
14ACX-018-230A TXV 19,300 14.50 12.20 C33-31A 7186907
14ACX-018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070E36B 7186912
14ACX-018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070XE36B 7186913
14ACX-018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH030XE24B 8608818
14ACX-018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH045XE24B 8608819
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.