14ACX - 1.5 to 5 Ton Air Conditioner / Page 138
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-024-230A TXV 24,000 14.50 12.20 CR33-30/36B 7174782
14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36C SLP98DF090XV36C 7174793
14ACX-024-230A TXV 24,000 14.50 12.20 CR33-30/36C 7174792
14ACX-024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045E36A 7174794
14ACX-024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045XE36A 7174795
14ACX-024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH030XE24B 8608882
14ACX-024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH045XE24B 8608883
14ACX-024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045E36A 7174799
14ACX-024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045XE36A 7174800
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070V36A 7174797
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070XV36A 7174798
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045E36A 7174804
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045XE36A 7174805
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070V36A 7174802
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070XV36A 7174803
14ACX-024-230A TXV 24,000 14.25 12.20 CX34-25A 7174801
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070E36B 7174813
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070XE36B 7174814
14ACX-024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH030XE24B 8608884
14ACX-024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH045XE24B 8608885
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH045XE36B 7174815
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH070XE36B 7174816
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XE36B 7174817
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XV36B 7174810
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XE36B 7174818
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XV36B 7174811
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V36B 7174807
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V48B 7174808
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090XV48B 7174809
14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SLP98UH070XV36B 7174812
14ACX-024-230A TXV 24,000 14.25 12.20 CX34-25B 7174806
14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045E36A 7174823
14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045XE36A 7174824
14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070V36A 7174821
14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070XV36A 7174822
14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070E36B 7174828
14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070XE36B 7174829
14ACX-024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH030XE24B 8608886
14ACX-024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH045XE24B 8608887
14ACX-024-230A TXV 23,000 15.10 12.50 CX34-30B EL195UH045XE36B 7174830
14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL195UH070XE36B 7174831
14ACX-024-230A TXV 23,000 15.10 12.50 CX34-30B EL296UH045XE36B 7174832
14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH045XV36B 7174834
14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL296UH070XE36B 7174833
14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH070XV36B 7174835
14ACX-024-230A TXV 23,600 15.10 13.00 CX34-30B SL280UH090V36B 7174825
14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090V48B 7174826
14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090XV48B 7174827
14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B SLP98UH070XV36B 7174836
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.