14ACX - 1.5 to 5 Ton Air Conditioner / Page 158
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL180UH090E60C 7513157
14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110E60C 7513158
14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110XE60C 7513159
14ACX-036-230A TXV 34,800 16.00 13.00 C33-49 EL195UH090XE48C 7513160
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL195UH110XE60C 7513162
14ACX-036-230A TXV 34,800 16.00 13.00 C33-49 EL296UH090XE48C 7513161
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH090XV36C 7513164
14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL296UH090XV48C 7513166
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XE60C 7513163
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XV48C 7513168
14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 EL296UH110XV60C 7513169
14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090V60C 7513153
14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090XV60C 7513154
14ACX-036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110V60C 7513155
14ACX-036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110XV60C 7513156
14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 SLP98UH090XV36C 7513165
14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 SLP98UH090XV48C 7513167
14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SLP98UH110XV60C 7513170
14ACX-036-230A TXV 34,600 14.50 12.20 C33-49 7513152
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH090E60C 7510374
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110E60C 7510375
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110XE60C 7510376
14ACX-036-230A TXV 34,600 15.50 12.50 C33-50/60C EL195UH090XE48C 7510377
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL195UH110XE60C 7510379
14ACX-036-230A TXV 34,600 15.50 12.50 C33-50/60C EL296UH090XE48C 7510378
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV36C 7510381
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV48C 7510383
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH110XE60C 7510380
14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C EL296UH110XV48C 7510385
14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C EL296UH110XV60C 7510386
14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090V60C 7510370
14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090XV60C 7510371
14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110V60C 7510372
14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110XV60C 7510373
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV36C 7510382
14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV48C 7510384
14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SLP98UH110XV60C 7510387
14ACX-036-230A TXV 34,200 14.50 12.20 C33-50/60C 7510369
14ACX-036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045E36A 8268054
14ACX-036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045XE36A 8268055
14ACX-036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070V36A 8268052
14ACX-036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070XV36A 8268053
14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070E36B 8268061
14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070XE36B 8268062
14ACX-036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090E48B 8268063
14ACX-036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090XE48B 8268064
14ACX-036-230A TXV 33,000 15.00 12.50 C35-30/36B EL195UH045XE36B 8268065
14ACX-036-230A TXV 33,000 15.00 12.50 C35-30/36B EL296UH045XE36B 8268056
14ACX-036-230A TXV 33,400 15.00 12.50 C35-30/36B EL296UH045XV36B 8268057
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.