14ACX - 1.5 to 5 Ton Air Conditioner / Page 16
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-041-230 TXV 40,000 16.00 14.00 CBX25UHV-048 6970130
14ACX-041-230 TXV 39,000 16.00 13.00 CBX27UH-048 3869097
14ACX-041-230 TXV 39,500 16.00 13.00 CBX32MV-048 3869098
14ACX-041-230 TXV 39,000 16.00 13.00 CBX40UHV-048 3869099
14ACX-041-230 TXV 37,600 15.50 13.00 CH23-51 EL180UH090E60C 5736596
14ACX-041-230 TXV 37,400 15.20 13.00 CH23-51 EL296UH110XV48C 5685140
14ACX-041-230 TXV 37,200 15.50 13.00 CH23-51 SL280UH090V60C 5514080
14ACX-041-230 TXV 38,000 15.50 13.00 CH23-65 EL180UH090E60C 5736598
14ACX-041-230 TXV 37,600 15.50 13.00 CH23-65 SL280UH090V60C 5514082
14ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090E48B 5735097
14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH090E60C 5735991
14ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090XE48B 5737061
14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110E60C 5737813
14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110XE60C 5738874
14ACX-041-230 TXV 39,000 15.00 12.70 CH33-43 EL296UH045XV36B 5153070
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV36C 5057187
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV48C 5057188
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV60C 5057189
14ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 EL296UH110XV60C 5057190
14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43 SL280UH090V36B 4253795
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV36C 5140458
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV48C 5140459
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV60C 5140460
14ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 SLP98UH110XV60C 5140461
14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090V48B 3869100
14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090XV48B 4038521
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL195UH090XE48C 4693855
14ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL195UH110XE60C 4694030
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL296UH090XE48C 5647240
14ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL296UH110XE60C 5647288
14ACX-041-230 TXV 39,000 15.70 13.50 CH33-43C EL296UH110XV48C 5685137
14ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090V60C 3869104
14ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090XV60C 4235236
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110V60C 3869105
14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110XV60C 4040073
14ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090E48B 5735098
14ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090XE48B 5737063
14ACX-041-230 TXV 38,000 14.70 12.50 CH33-44/48 EL296UH045XV36B 5153071
14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH090E60C 5735993
14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110E60C 5737815
14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110XE60C 5738875
14ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 EL296UH090XV36C 5057191
14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 EL296UH090XV48C 5057192
14ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 SLP98UH090XV36C 5140515
14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 SLP98UH090XV48C 5140516
14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL195UH090XE48C 4693856
14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL195UH110XE60C 4693869
14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL296UH090XE48C 5647241
14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL296UH110XE60C 5647254
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.