EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 167

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 167
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A TXV 33,400 15.10 12.50 CH35-36B EL180UH090XE48B 7510627
14ACX-036-230A TXV 33,000 15.00 12.50 CH35-36B EL195UH045XE36B 7510628
14ACX-036-230A TXV 33,000 15.00 12.50 CH35-36B EL296UH045XE36B 7510629
14ACX-036-230A TXV 33,600 15.00 12.20 CH35-36B EL296UH045XV36B 7510632
14ACX-036-230A TXV 33,400 15.00 12.50 CH35-36B EL296UH070XV36B 7510633
14ACX-036-230A TXV 33,600 15.50 12.50 CH35-36B SL280UH090V36B 7510621
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090V48B 7510622
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090XV48B 7510623
14ACX-036-230A TXV 33,400 15.00 12.50 CH35-36B SLP98UH070XV36B 7510634
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL180UH090E60C 7510638
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110E60C 7510639
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110XE60C 7510640
14ACX-036-230A TXV 33,600 15.10 12.50 CH35-36C EL195UH090XE48C 7510641
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL195UH110XE60C 7510643
14ACX-036-230A TXV 33,600 15.10 12.50 CH35-36C EL296UH090XE48C 7510642
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH090XV36C 7510645
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL296UH090XV48C 7510647
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XE60C 7510644
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XV48C 7510649
14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C EL296UH110XV60C 7513215
14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090V60C 7513213
14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090XV60C 7513214
14ACX-036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110V60C 7510636
14ACX-036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110XV60C 7510637
14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C SLP98UH090XV36C 7510646
14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C SLP98UH090XV48C 7510648
14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SLP98UH110XV60C 7510650
14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070E36B 7510655
14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070XE36B 7510656
14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090E48B 7510657
14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090XE48B 7510658
14ACX-036-230A TXV 35,000 15.10 12.50 CH35-42B EL195UH045XE36B 7510659
14ACX-036-230A TXV 35,200 15.10 12.50 CH35-42B EL195UH070XE36B 7510661
14ACX-036-230A TXV 35,000 15.10 12.50 CH35-42B EL296UH045XE36B 7510660
14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH045XV36B 7510663
14ACX-036-230A TXV 35,200 15.10 12.50 CH35-42B EL296UH070XE36B 7510662
14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH070XV36B 7510664
14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B SL280UH090V36B 7510652
14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090V48B 7510653
14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090XV48B 7510654
14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B SLP98UH070XV36B 7510665
14ACX-036-230A TXV 35,000 14.50 12.20 CH35-42B 7510651
14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL180UH090E60C 7510671
14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110E60C 7510672
14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110XE60C 7510673
14ACX-036-230A TXV 34,800 16.00 13.00 CH35-42C EL195UH090XE48C 7510674
14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL195UH110XE60C 7510676
14ACX-036-230A TXV 34,800 16.00 13.00 CH35-42C EL296UH090XE48C 7510675
14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH090XV36C 7510678
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.