14ACX - 1.5 to 5 Ton Air Conditioner / Page 183
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV60C 7511135
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-51 SL280UH090V60C 7511136
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110V60C 7511137
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110XV60C 7511138
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV48C 7511139
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV60C 7511140
14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH110XV60C 7511141
14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH090E60C 7511142
14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110E60C 7511143
14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110XE60C 7511144
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV48C 7511145
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV60C 7511146
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV48C 7511147
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV60C 7511148
14ACX-042-230A TXV 41,000 15.50 12.50 CH23-65 SL280UH090V60C 7511149
14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110V60C 7511150
14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110XV60C 7511151
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV48C 7511152
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV60C 7511153
14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH110XV60C 7511154
14ACX-042-230A TXV 40,500 15.10 12.50 CH33-42 EL180UH090E48B 7511155
14ACX-042-230A TXV 40,500 15.10 12.50 CH33-42 EL180UH090XE48B 7511156
14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090V36B 7511158
14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090V48B 7511159
14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090XV48B 7511160
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090E48B 8565947
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090XE48B 8565948
14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH045XV36B 7511162
14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH070XV36B 7511164
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V36B 7511165
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V48B 7511166
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090XV48B 7511167
14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B SLP98UH070XV36B 7511163
14ACX-042-230A TXV 41,000 14.50 12.20 CH33-43B SLP98UH090XV36B 7511168
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH090E60C 7511170
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110E60C 7511171
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110XE60C 7511172
14ACX-042-230A TXV 41,000 15.50 12.50 CH33-43C EL195UH090XE48C 7511173
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL195UH110XE60C 7511174
14ACX-042-230A TXV 41,000 15.50 12.50 CH33-43C EL296UH090XE48C 7511175
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV36C 7511176
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV48C 7511177
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV60C 7511178
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XE60C 7511179
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV48C 7511180
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV60C 7511181
14ACX-042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090V60C 7511182
14ACX-042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090XV60C 7511183
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110V60C 7511184
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.