EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 184

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 184
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110XV60C 7511185
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV36C 7511186
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV48C 7511187
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV60C 7511188
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH110XV60C 7511189
14ACX-042-230A TXV 41,500 14.00 12.20 CH33-43C 7511169
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090E48B 7511190
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090XE48B 7511191
14ACX-042-230A TXV 40,500 14.50 12.20 CH33-44/48B EL296UH070XV36B 7511192
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V36B 7511193
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V48B 7511194
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090XV48B 7511195
14ACX-042-230A TXV 40,500 14.50 12.20 CH33-44/48B SLP98UH070XV36C 7511196
14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH090E60C 7511197
14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110E60C 7511198
14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110XE60C 7511199
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL195UH090XE48C 7511200
14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL195UH110XE60C 7511201
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XE48C 7511202
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV36C 7511203
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV48C 7511204
14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH090XV60C 7511205
14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH110XE60C 7511206
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV48C 7511207
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV60C 7511208
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090V60C 7511209
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090XV60C 7511210
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110V60C 7511211
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110XV60C 7511212
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV36C 7511213
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV48C 7511214
14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C SLP98UH090XV60C 7511215
14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH110XV60C 7511216
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH090E60C 7511219
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110E60C 7511220
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110XE60C 7511221
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL195UH090XE48C 7511222
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL195UH110XE60C 7511223
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XE48C 7511224
14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XV36C 7511225
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV48C 7511226
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV60C 7511227
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XE60C 7511228
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV48C 7511229
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV60C 7511230
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090V60C 7511231
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090XV60C 7511232
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110V60C 7511233
14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110XV60C 7511234
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.