14ACX - 1.5 to 5 Ton Air Conditioner / Page 26
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-047-230 TXV 47,000 15.50 13.00 CH35-60D SL280UH135V60D 7164083
14ACX-047-230 TXV 47,000 15.50 12.50 CH35-60D SLP98UH135V60D 7164086
14ACX-047-230 TXV 47,000 14.50 12.00 CH35-60D 7164073
14ACX-047-230 TXV 45,000 15.20 12.50 CR33-50/60 EL180DF110E60C 5733507
14ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL195DF090XE48C 4693917
14ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL195DF110XE60C 4693918
14ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL296DF090XE48C 5647262
14ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL296DF110XE60C 5647263
14ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF090V60C 3869186
14ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF110V60C 3869187
14ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090E48B 5735116
14ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090XE48B 5737081
14ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090V48B 4016676
14ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090XV48B 4038533
14ACX-047-230 TXV 46,000 14.25 12.00 CX34-43C 7426649
14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110E60C 5737884
14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110XE60C 5738944
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090E48B 5735118
14ACX-047-230 TXV 45,000 15.00 12.50 CX34-44/48 EL180UH090E60C 5736026
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090XE48B 5737083
14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110E60C 5737884
14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110XE60C 5738944
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH090XE48C 4693927
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH110XE60C 4693939
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XE48C 5647272
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XV48C 5057272
14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 EL296UH090XV60C 5057273
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XE60C 5647235
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XV60C 5057274
14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090V48B 4016677
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090V60C 3869194
14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090XV48B 4038534
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090XV60C 4235243
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110V60C 3869195
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110XV60C 4040147
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH090XV48C 5140462
14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SLP98UH090XV60C 5140463
14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH110XV60C 5140464
14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 EL180UH090E60C 5736028
14ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110E60C 5737850
14ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110XE60C 5738926
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL195UH090XE48C 4693928
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL195UH110XE60C 4693940
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XE48C 5647273
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XV48C 5057281
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH090XV60C 5057282
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XE60C 5647276
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XV60C 5057283
14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH090V60C 4253836
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.