14ACX - 1.5 to 5 Ton Air Conditioner / Page 27
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH110V60C 4253837
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 SLP98UH090XV48C 5140524
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH090XV60C 5140525
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH110XV60C 5140526
14ACX-047-230 TXV 46,500 14.50 12.00 CX34-49 7426653
14ACX-047-230 TXV 45,500 15.20 12.50 CX34-50/60C EL180UH090E60C 5736030
14ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110E60C 5737851
14ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110XE60C 5738929
14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH090XE48C 4693929
14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH110XE60C 4693941
14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH090XE48C 5647274
14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH110XE60C 5647277
14ACX-047-230 TXV 45,500 14.25 12.00 CX34-50/60C 7426657
14ACX-047-230 TXV 47,000 15.70 13.00 CX34-60D EL180UH135E60D 5746072
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL195UH135XE60D 4693947
14ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL296UH135XE60D 5647283
14ACX-047-230 TXV 46,500 14.50 12.00 CX34-60D 7426654
14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH090E60C 5736032
14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110E60C 5737854
14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110XE60C 5738931
14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH090XE48C 4693930
14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH110XE60C 4693942
14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH090XE48C 5647275
14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH110XE60C 5647278
14ACX-047-230 TXV 48,000 16.00 13.00 CX34-62C SL280UH090V60C 4253841
14ACX-047-230 TXV 47,500 16.00 13.00 CX34-62C SL280UH110V60C 4253842
14ACX-047-230 TXV 47,000 14.50 12.50 CX34-62C 3869197
14ACX-047-230 TXV 47,500 15.70 13.20 CX34-62D EL180UH135E60D 5746073
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL195UH135XE60D 4693948
14ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL296UH135XE60D 5647284
14ACX-047-230 TXV 47,000 14.50 12.00 CX34-62D 7426655
14ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090E48B 8267433
14ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090XE48B 8267432
14ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090V48B 8267435
14ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090XV48B 8267434
14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110E60C 8267436
14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110XE60C 8267437
14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL195UH090XE48C 8267447
14ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL195UH110XE60C 8267446
14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL296UH090XE48C 8267438
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV48C 8267443
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV60C 8267444
14ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL296UH110XE60C 8267439
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH110XV60C 8267445
14ACX-047-230 TXV 47,000 15.50 12.50 CX35-49C SL280UH090V60C 8267448
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SL280UH110V60C 8267449
14ACX-047-230 TXV 47,000 15.00 12.50 CX35-49C SLP98UH090XV48C 8267441
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH090XV60C 8267442
14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH110XV60C 8267440
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.