AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C SLP98UH110XV60C 7163553
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C 7163562
14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D EL180UH135E60D 7163567
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-60D EL195UH135XE60D 7163564
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-60D EL296UH135XE60D 7163566
14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D EL296UH135XV60D 7163565
14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D SL280UH135V60D 7163568
14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D SLP98UH135XV60D 7163569
14ACX-059-230 TXV 56,500 14.50 12.00 CH35-60D 7163563
14ACX-059-230 TXV 56,000 15.00 12.20 CR33-50/60 EL180DF110E60C 5733537
14ACX-059-230 TXV 55,500 14.50 12.00 CR33-50/60 EL195DF110XE60C 5053220
14ACX-059-230 TXV 55,500 14.50 12.00 CR33-50/60 EL296DF110XE60C 5648038
14ACX-059-230 TXV 55,500 14.70 12.00 CR33-50/60 SL280DF090V60C 5053176
14ACX-059-230 TXV 56,000 14.70 12.20 CR33-50/60 SL280DF110V60C 5053177
14ACX-059-230 TXV 56,500 14.20 11.70 CR33-50/60 SLP98DF090XV60C 5141545
14ACX-059-230 TXV 55,500 14.20 11.70 CR33-50/60 SLP98DF110XV60C 5141546
14ACX-059-230 TXV 55,500 14.20 11.70 CR33-50/60 5053094
14ACX-059-230 TXV 55,500 14.20 11.70 CR33-60 5053090
14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH090E60C 5736405
14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH110E60C 5738221
14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH110XE60C 5739172
14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 EL195UH110XE60C 5053225
14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 EL296UH110XE60C 5648043
14ACX-059-230 TXV 56,500 14.70 12.00 CX34-49 EL296UH110XV60C 5431230
14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 SL280UH090V60C 5053134
14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 SL280UH110V60C 5053135
14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 SL280UH110XV60C 5053136
14ACX-059-230 TXV 57,000 14.70 12.00 CX34-49 SLP98UH090XV60C 5141558
14ACX-059-230 TXV 56,500 14.70 12.00 CX34-49 SLP98UH110XV60C 5141554
14ACX-059-230 TXV 57,000 14.50 12.00 CX34-49 5053091
14ACX-059-230 TXV 56,500 14.00 11.70 CX34-50/60C EL180UH090E60C 5736408
14ACX-059-230 TXV 56,000 14.00 11.70 CX34-50/60C EL180UH110E60C 5738224
14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C SL280UH090V60C 5053140
14ACX-059-230 TXV 55,500 14.20 12.00 CX34-50/60C SL280UH110V60C 5053141
14ACX-059-230 TXV 55,500 14.20 12.00 CX34-50/60C SL280UH110XV60C 5053142
14ACX-059-230 TXV 55,500 14.00 11.70 CX34-50/60C SLP98UH090XV60C 5141555
14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C SLP98UH110XV60C 5141556
14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C 5053092
14ACX-059-230 TXV 57,000 15.00 12.20 CX34-60D EL180UH135E60D 5746020
14ACX-059-230 TXV 56,500 14.70 12.00 CX34-60D EL195UH135XE60D 5053230
14ACX-059-230 TXV 56,500 14.70 12.00 CX34-60D EL296UH135XE60D 5648048
14ACX-059-230 TXV 57,000 15.00 12.20 CX34-60D EL296UH135XV60D 5431231
14ACX-059-230 TXV 57,000 14.70 12.20 CX34-60D SL280UH135V60D 5053146
14ACX-059-230 TXV 56,500 15.00 12.20 CX34-60D SLP98UH135XV60D 5141557
14ACX-059-230 TXV 56,500 14.50 12.00 CX34-60D 5053093
14ACX-059-230 TXV 58,000 15.50 12.70 CX34-62C EL180UH090E60C 5736410
14ACX-059-230 TXV 57,500 15.20 12.50 CX34-62C EL180UH110E60C 5738226
14ACX-059-230 TXV 57,500 14.70 12.20 CX34-62C EL180UH110XE60C 5739176
14ACX-059-230 TXV 57,000 14.50 12.20 CX34-62C EL195UH110XE60C 5053244
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.