AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SL280UH110V60C 8309451
14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SL280UH110XV60C 8309452
14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SLP98UH090XV60C 8309453
14ACX-059-230 TXV 57,500 15.00 12.20 CX35-60C SLP98UH110XV60C 8309454
14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60C 8309455
14ACX-059-230 TXV 57,500 15.10 12.50 CX35-60D EL180UH135E60D 8309467
14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60D EL195UH135XE60D 8309468
14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60D EL296UH135XE60D 8309470
14ACX-059-230 TXV 57,500 15.00 12.20 CX35-60D EL296UH135XV60D 8309469
14ACX-059-230 TXV 57,000 15.50 12.50 CX35-60D SL280UH135V60D 8309471
14ACX-059-230 TXV 57,000 14.50 11.70 CX35-60D 8309472
14ACX-060-230 TXV 58,000 14.50 12.00 C33-49 EL180UH090E60C 5736959
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL180UH110E60C 5738738
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL180UH110XE60C 5739577
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL195UH110XE60C 5697671
14ACX-060-230 TXV 57,000 14.20 11.70 C33-49 EL296UH090XV60C 5699645
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL296UH110XE60C 5697672
14ACX-060-230 TXV 57,000 14.20 12.00 C33-49 EL296UH110XV60C 5699646
14ACX-060-230 TXV 58,000 14.20 12.00 C33-49 SL280UH090V60C 5697678
14ACX-060-230 TXV 58,000 14.20 12.00 C33-49 SL280UH090XV60C 5697680
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 SL280UH110V60C 5697679
14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 SL280UH110XV60C 5697681
14ACX-060-230 TXV 57,000 14.20 11.70 C33-49 SLP98UH090XV60C 5697673
14ACX-060-230 TXV 57,000 14.20 12.00 C33-49 SLP98UH110XV60C 5697674
14ACX-060-230 TXV 58,000 14.00 11.70 C33-49 5697670
14ACX-060-230 TXV 56,500 14.20 11.70 C33-50/60C EL180UH090E60C 5736961
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL180UH110E60C 5738740
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL180UH110XE60C 5739579
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL195UH110XE60C 5697683
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL296UH110XE60C 5697684
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C SL280UH090V60C 5697689
14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C SL280UH090XV60C 5697691
14ACX-060-230 TXV 58,000 14.50 12.00 C33-60D EL180UH135E60D 5745978
14ACX-060-230 TXV 58,000 14.00 11.70 C33-60D EL195UH135XE60D 5697696
14ACX-060-230 TXV 58,000 14.00 11.70 C33-60D EL296UH135XE60D 5697697
14ACX-060-230 TXV 57,500 14.50 12.00 C33-60D EL296UH135XV60D 5697698
14ACX-060-230 TXV 57,500 14.70 12.20 C33-60D SL280UH135V60D 5697700
14ACX-060-230 TXV 57,500 14.50 12.00 C33-60D SLP98UH135XV60D 5697701
14ACX-060-230 TXV 57,500 14.00 11.70 C33-60D 5697695
14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C EL180UH090E60C 5736957
14ACX-060-230 TXV 58,500 14.70 12.20 C33-62C EL180UH110E60C 5738736
14ACX-060-230 TXV 58,500 14.70 12.20 C33-62C EL180UH110XE60C 5739575
14ACX-060-230 TXV 58,500 14.50 12.00 C33-62C EL195UH110XE60C 5697703
14ACX-060-230 TXV 58,000 14.50 12.00 C33-62C EL296UH090XV60C 5697705
14ACX-060-230 TXV 58,500 14.50 12.00 C33-62C EL296UH110XE60C 5697704
14ACX-060-230 TXV 58,000 14.50 12.20 C33-62C EL296UH110XV60C 5697706
14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C SL280UH090V60C 5697710
14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C SL280UH090XV60C 5697712
14ACX-060-230 TXV 58,500 14.50 12.20 C33-62C SL280UH110V60C 5697711
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.