14ACX - 1.5 to 5 Ton Air Conditioner / Page 85
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 34,600 15.50 12.50 C33-38B SLP98UH070XV36B 7782575
14ACXS036-230A TXV 34,200 14.25 12.20 C33-38B 7626196
14ACXS036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070E36B 7783162
14ACXS036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070XE36B 7628306
14ACXS036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090E48B 7783163
14ACXS036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090XE48B 7628309
14ACXS036-230A TXV 33,000 15.00 12.50 C33-42 EL195UH045XE36B 7783164
14ACXS036-230A TXV 33,200 14.50 12.00 C33-42 EL195UH070XE36B 7783165
14ACXS036-230A TXV 33,000 15.00 12.50 C33-42 EL296UH045XE36B 7628312
14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH045XV36B 7783166
14ACXS036-230A TXV 33,200 14.50 12.00 C33-42 EL296UH070XE36B 7628315
14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH070XV36B 7628318
14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V36B 7628300
14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V48B 7783161
14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090XV48B 7628303
14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 SLP98UH070XV36B 7783167
14ACXS036-230A TXV 33,000 14.00 11.50 C33-42 7783160
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070E36B 7626230
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070XE36B 7782578
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090E48B 7626233
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090XE48B 7782579
14ACXS036-230A TXV 34,400 15.00 12.50 C33-43B EL195UH045XE36B 7626236
14ACXS036-230A TXV 34,600 15.10 12.50 C33-43B EL195UH070XE36B 7626239
14ACXS036-230A TXV 34,400 15.00 12.50 C33-43B EL296UH045XE36B 7782580
14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH045XV36B 7626242
14ACXS036-230A TXV 34,600 15.10 12.50 C33-43B EL296UH070XE36B 7782581
14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH070XV36B 7782582
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B SL280UH090V36B 7782576
14ACXS036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090V48B 7626227
14ACXS036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090XV48B 7782577
14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B SLP98UH070XV36B 7626245
14ACXS036-230A TXV 34,400 14.50 12.20 C33-43B 7626224
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH090E60C 7626254
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110E60C 7782586
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110XE60C 7626257
14ACXS036-230A TXV 34,600 15.50 12.50 C33-43C EL195UH090XE48C 7782587
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL195UH110XE60C 7782588
14ACXS036-230A TXV 34,600 15.50 12.50 C33-43C EL296UH090XE48C 7626260
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV36C 7782589
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV48C 7782590
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH110XE60C 7626263
14ACXS036-230A TXV 35,000 16.00 13.00 C33-43C EL296UH110XV48C 7782591
14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C EL296UH110XV60C 7626273
14ACXS036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090V60C 7626248
14ACXS036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090XV60C 7782584
14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110V60C 7626251
14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110XV60C 7782585
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV36C 7626267
14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV48C 7626270
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.