14ACX - 1.5 to 5 Ton Air Conditioner / Page 86
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SLP98UH110XV60C 7782592
14ACXS036-230A TXV 34,400 14.50 12.20 C33-43C 7782583
14ACXS036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070E36B 7626283
14ACXS036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070XE36B 7782595
14ACXS036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090E48B 7626286
14ACXS036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090XE48B 7782596
14ACXS036-230A TXV 33,800 15.10 12.50 C33-48B EL195UH045XE36B 7626289
14ACXS036-230A TXV 34,200 15.00 12.50 C33-48B EL195UH070XE36B 7626292
14ACXS036-230A TXV 33,800 15.10 12.50 C33-48B EL296UH045XE36B 7782597
14ACXS036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH045XV36B 7626296
14ACXS036-230A TXV 34,200 15.00 12.50 C33-48B EL296UH070XE36B 7782598
14ACXS036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH070XV36B 7782599
14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V36B 7782593
14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V48B 7626280
14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090XV48B 7782594
14ACXS036-230A TXV 34,000 15.10 12.50 C33-48B SLP98UH070XV36B 7626299
14ACXS036-230A TXV 33,800 14.50 12.00 C33-48B 7626276
14ACXS036-230A TXV 34,200 15.10 12.50 C33-48C EL195UH090XE48C 7626302
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL195UH110XE60C 7626305
14ACXS036-230A TXV 34,200 15.10 12.50 C33-48C EL296UH090XE48C 7782601
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV36C 7626309
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV48C 7626312
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH110XE60C 7782602
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV36C 7782603
14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV48C 7782604
14ACXS036-230A TXV 33,800 14.50 12.00 C33-48C 7782600
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL180UH090E60C 7628336
14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110E60C 7783172
14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110XE60C 7628341
14ACXS036-230A TXV 34,800 16.00 13.00 C33-49 EL195UH090XE48C 7783173
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL195UH110XE60C 7783174
14ACXS036-230A TXV 34,800 16.00 13.00 C33-49 EL296UH090XE48C 7628344
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH090XV36C 7783175
14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL296UH090XV48C 7783176
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XE60C 7628347
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XV48C 7783177
14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 EL296UH110XV60C 7628356
14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090V60C 7628328
14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090XV60C 7783170
14ACXS036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110V60C 7628333
14ACXS036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110XV60C 7783171
14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 SLP98UH090XV36C 7628350
14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 SLP98UH090XV48C 7628353
14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SLP98UH110XV60C 7783178
14ACXS036-230A TXV 34,600 14.50 12.20 C33-49 7783169
14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH090E60C 7626325
14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110E60C 7782608
14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110XE60C 7626328
14ACXS036-230A TXV 34,600 15.50 12.50 C33-50/60C EL195UH090XE48C 7782609
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.