LGH/LCH036, 048, 060, 072, 074
LGH/LCH074H CHARGING CURVE - ALL-ALUMINUM COIL
Suction Pressure
(p
si
g)
60
70
80
90
100
110
120
130
110 120 130 140 150 160
Outdoor Temperature (°F)
170 180
105°
95°
115°
85°
75°
65°
LGH/LCH074H REHEAT CHARGING CURVE - ALL-ALUMINUM COIL
Suction Pressure
(p
si
g)
70
80
90
100
110
120
130
110 120 130 140 150 160
Outdoor Temperature (°F)
170 180
105°
95°
115°
85°
75°
65°