EasyManuals Logo

Lennox LGH074 Installation Instructions

Lennox LGH074
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Page 54
LGH/LCH036, 048, 060, 072, 074
LGH/LCH074H CHARGING CURVE - ALL-ALUMINUM COIL
Suction Pressure
(p
si
g)
60
70
80
90
100
110
120
130
110 120 130 140 150 160
Outdoor Temperature (°F)
170 180
105°
95°
115°
85°
75°
65°
LGH/LCH074H REHEAT CHARGING CURVE - ALL-ALUMINUM COIL
Suction Pressure
(p
si
g)
70
80
90
100
110
120
130
110 120 130 140 150 160
Outdoor Temperature (°F)
170 180
105°
95°
115°
85°
75°
65°

Other manuals for Lennox LGH074

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox LGH074 and is the answer not in the manual?

Lennox LGH074 Specifications

General IconGeneral
BrandLennox
ModelLGH074
CategoryAccessories
LanguageEnglish

Related product manuals