BLOWER DATA
SLP98UH110XV60C BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 805 893 1068 1243 1419 1594 1770 1945
Increase (+7.5%) Heat CFM 729 814 986 1157 1329 1500 1672 1843
Default Heat CFM 652 736 903 1071 1238 1406 1573 1741
Decrease (-7.5% ) Heat CFM 603 680 833 986 1139 1293 1446 1599
Decrease (-15% ) Heat CFM 554 623 762 901 1040 1179 1318 1457
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 1020 1205 1305 1480 1485 1725 1885 2070
Default Cool CFM 955 1080 1205 1360 1365 1565 1720 1905
Decrease (-10%) Cool CFM 865 980 1080 1215 1220 1390 1545 1740
SLP98UH110XV60C BLOWER MOTOR WATTS - COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Increase (+10%) Cool CFM
Low 67 95 127 145 178 201 235 260 289 197 235 271 319 349 391 435 462 509 547 583
Medium-Low 111 139 173 194 228 259 288 314 343 316 348 399 440 485 523 571 604 646 689 717
Medium-High 142 179 207 237 275 305 340 378 407 463 499 549 579 628 674 721 758 803 840 859
High 197 235 271 319 349 391 435 462 509 618 641 712 776 818 857 914 963 992 1042 1079
Default Cool CFM
Low 53 81 100 124 147 173 201 223 248 149 188 215 251 289 321 350 391 422 469 490
Medium-Low 77 104 135 160 193 217 246 276 302 229 259 303 347 391 427 462 501 532 576 605
Medium-High 110 141 170 200 230 256 292 322 346 334 363 419 459 510 546 586 635 679 704 739
High 149 188 215 251 289 321 350 391 422 480 523 558 607 651 707 740 782 838 863 899
Decrease (-10%) Cool CFM
Low 45 64 89 106 129 148 173 191 211 111 140 171 202 231 259 291 320 347 379 410
Medium-Low 57 85 111 133 155 182 215 239 262 158 194 224 264 304 340 369 403 445 481 510
Medium-High 77 104 135 160 193 217 246 276 302 229 261 315 344 391 431 470 505 544 586 623
High 111 140 171 202 231 259 291 320 347 366 402 440 486 531 578 616 660 686 724 763
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 450 cfm.