Check/VerifyFRU/Action
Checkthefollowingforproperinstallation.
•Powercord
•On/Offswitchconnector
•On/Offswitchpowersupplyconnector
•Systemboardpowersupplyconnectors
•Microprocessor(s)connection
Reseatconnectors
Checkthepowercordforcontinuity.
Powercord
Checkthepower-onswitchforcontinuity.
Power-onswitch
Diagnosticerrorcodes
Refertothefollowingdiagnosticerrorcodeswhenusingthediagnostictests.See“Runningtests”onpage
35forthespecictypeforinformationaboutthediagnosticprograms.
Inthefollowingindex,Xcanrepresentanynumber.
DiagnosticErrorCodeFRU/Action
000-000-XXXBIOSTestPassed
Noaction
000-002-XXXBIOSTimeout1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
000-024-XXXBIOSAddressingtestfailure1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
000-025-XXXBIOSChecksumValueerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
000-026-XXXFLASHdataerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
000-027-XXXBIOSConguration/Setuperror1.RunSetup
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98
3.Systemboard
000-034-XXXBIOSBufferAllocationfailure
1.Rebootthesystem
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98
3.Runmemorytest
4.Systemboard
000-035-XXXBIOSResetConditiondetected1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
000-036-XXXBIOSRegistererror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage98.
2.Systemboard
44ThinkCentreHardwareMaintenanceManual