Formoreinformationabouttheharddiskdriveenablementmodule,see“Installingorreplacingaharddisk
driveenablementmodule”onpage52
.
ConfiguringSATAorSASRAIDfunctionalitywithIntelRSTeconfiguration
utility
ThissectiondescribestheinformationaboutconfiguringSATAorSASRAIDfunctionalitywiththeIntel
RSTeconfigurationutility.
Note:TheIntelRSTeconfigurationutilityassumesthatyourcomputerisinstalledwithmorethanonehard
diskdrive.Therefore,ifonlyoneharddiskdriveisinstalledinyourcomputer,thefollowinginformation
doesnotapply.
Thissectionprovidesinformationaboutthefollowingtopics:
•“EnteringtheIntelRSTeconfigurationutility”onpage82
•“CreatingRAIDvolumesusingtheIntelRSTeconfigurationutility”onpage82
•“DeletingRAIDvolumesusingtheIntelRSTeconfigurationutility”onpage83
•“Resettingharddiskdrivestonon-RAID”onpage83
EnteringtheIntelRSTeconfigurationutility
ThissectionprovidesinstructionsonhowtoentertheIntelRSTeconfigurationutility.
Duringthecomputerstartup,followtheinstructionsonthescreen.PressCtrl+ItoentertheIntelRSTe
configurationutility.
ThefollowingfouroptionsaredisplayedafteryouentertheIntelRSTeconfigurationutility.
1.CreateRAIDVolume
2.DeleteRAIDVolume
3.ResetDiskstoNon-RAID
4.Exit
Presstheupanddownarrowkeystoselectanoption.PressEntertoentertheselectedmenu.Press
EsctoexittheIntelRSTeconfigurationutility,orselectExit,andthenpressEntertoexittheIntelRSTe
configurationutility.
CreatingRAIDvolumesusingtheIntelRSTeconfigurationutility
ThissectionprovidesinstructionsonhowtousetheIntelRSTeconfigurationutilitytocreateRAIDvolumes.
TocreateaRAIDvolume,dothefollowing:
1.EntertheIntelRSTeconfigurationutility.See“EnteringtheIntelRSTeconfigurationutility”onpage82.
2.PresstheupanddownarrowkeystoselectCreateRAIDVolume,andthenpressEntertoviewthe
CREATEVOLUMEMENUwindow.
3.Thefollowingfiveoptionsaredisplayed.Presstheupanddownarrowkeystoselectanoption.After
youconfigureanoption,pressTaborEntertogotothenextoption.
a.Name:Volumename.Youcanusethedefaultnameortypeapreferredname.
82ThinkStationC30UserGuide