Figure 24. Removal of a PSU filler
c. If more than one power supply units are to be installed, start with the lowest available number
of PSU slot.
Step 2. Insert the hot-swap power supply into the slot until the release latch clicks into place.
Important:
During normal operation, each power-supply slot must contain either a power supply or power-
supply filler for proper cooling.
Make sure to follow the instruction on the guiding label in each slot. For slot 1, the power supply
unit must be installed with the fan downward; for slots 2 and 3, the power supply units must be
installed with the fan upward.
After docking the power supply, hold the handle and slightly pull the power supply to make sure
that it is securely engaged and cannot be pulled out.