Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFIO0009M An inter-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
Warning
FQXSFIO0013I The device found at Bus [arg1] Device [arg2] Function [arg3] could not
be configured due to resource constraints. The Vendor ID for the
device is [arg4] and the Device ID is [arg5]. The physical slot number
is [arg6].
Warning
FQXSFIO0016M
IFM: Reset loop avoided - Multiple resets not allowed. Warning
FQXSFIO0021J PCIe Error Recovery has occurred in physical [arg1] number [arg2].
The [arg3] may not operate correctly.
Warning
FQXSFIO0022J PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFIO0023J PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFIO0024I An error has been detected by the IEH on processor [arg1]. The type
of IEH is [arg2]. The index of the IEH is [arg3]. The value of
IehErrorStatus register is [arg4]. Please check error logs for additional
downstream device error data.
Warning
FQXSFIO0025I An error has been detected by the IIO on processor [arg1]. The index
of the IIO stack is [arg2]. The type of IIO Internal Error is [arg3]. Please
check error logs for additional downstream device error data.
Warning
FQXSFIO0032M PCIe Correctable Error PFA Threshold limit has been exceeded at Bus
[arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is
[arg4] and the Device ID is [arg5]. The physical bay number is [arg6].
Warning
FQXSFIO0033J PCIe Link Width has degraded from [arg1] to [arg2] in physical bay
number [arg3].
Warning
FQXSFIO0034J PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay
number [arg3].
Warning
FQXSFMA0012L The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
Warning
FQXSFMA0016M Memory spare copy failed. [arg1] Warning
FQXSFMA0026G Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR)
Warning
FQXSFMA0027M DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
FQXSFMA0030K Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]%
and still functioning.
Warning
FQXSFMA0031K Intel Optane PMEM [arg1] has reached 1% remaining spares block
and still functioning.
Warning
FQXSFMA0033M Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning