Loading...
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0042
User Action:
Reflash the XCC firmware to the latest version.
FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt
to flash the XCC firmware to the same level on all nodes/servers.
A mismatch of XCC firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0132
User Action:
Attempt to flash the XCC firmware to the same level on all nodes.
FQXSPUP4005I: FPGA firmware mismatch between nodes/servers [arg1] and [arg2]. Please
attempt to flash the FPGA firmware to the same level on all nodes/servers.
A mismatch of FPGA firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0133
User Action:
Attempt to flash the FPGA firmware to the same level on all nodes.
FQXSPWD0000I: Watchdog Timer expired for [WatchdogElementName].
This message is for the use case when an implementation has detected a Watchdog Timer Expired.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0368
User Action:
Information only; no action is required
FQXSPWD0001I: Reboot of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName].