100%: Memory Mode
Go to Goals Memory Mode [%], input the memory percentage, and reboot the system.
Notes:
Before changing from one mode to another:
1. Back up all the data and delete all the created namespaces. Go to Namespaces View/
Modify/Delete Namespaces to delete the created namespaces.
2. Perform secure erase on all the installed PMEMs. Go to Security Press to Secure Erase to
perform secure erase.
Make sure the capacity of installed PMEM and DRAM DIMMs meets system requirements for the
new mode (see “PMEM rules” on page 155).
After the system is rebooted and the input goal value is applied, the displayed value in System
Configuration and Boot Management Intel Optane PMEMs Goals will go back to the
following default selectable options:
Scope: [Platform]
Memory Mode [%]: 0
Persistent Memory Type: [App Direct]
These values are selectable options for PMEM settings, and do not represent the current PMEM
status.
In addition, you can take advantage of a memory configurator, which is available at the following site:
http://1config.lenovo.com/#/memory_configuration
Alternatively, set PMEM Goals with the following commands in OneCLI:
For Memory Mode:
1. Set create goal status.
OneCli.exe config set IntelOptanePMEM.CreateGoal Yes
--bmc USERID:PASSW0RD@10.104.195.86
2. Define the PMEM capacity that is invested in system volatile memory.
OneCli.exe config set IntelOptanePMEM.MemoryModePercentage 100
--bmc USERID:PASSW0RD@10.104.195.86
Where 100 stands for the percentage of capacity that is invested in system volatile memory.
For App Direct Mode:
1. Set create goal status.
OneCli.exe config set IntelOptanePMEM.CreateGoal Yes
--bmc USERID:PASSW0RD@10.104.195.86
2. Define the PMEM capacity that is invested in system volatile memory.
OneCli.exe config set IntelOptanePMEM.MemoryModePercentage 0
--bmc USERID:PASSW0RD@10.104.195.86
Where 0 stands for the percentage of capacity that is invested in system volatile memory.
3. Set the PMEM mode.
OneCli.exe config set IntelOptanePMEM.PersistentMemoryType "App Direct"
--bmc USERID:PASSW0RD@10.104.195.86
Where App Direct stands for the PMEM mode. You can input App Direct for App Direct
interleaved or App Direct Not Interleaved for App Direct not interleaved.
Persistent Memory Type
Chapter 4. Hardware replacement procedures 157