Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPIO0004L A bus timeout has occurred on bus [SensorElementName]. Error
FQXSPIO0006N A software NMI has occurred on system
[ComputerSystemElementName].
Error
FQXSPIO0011N An Uncorrectable Error has occurred on [SensorElementName]. Error
FQXSPIO0013N A Fatal Bus Error has occurred on bus [SensorElementName].
Error
FQXSPIO0015M Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Error
FQXSPMA0006N Parity Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Error
FQXSPMA0012M An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Error
FQXSPOS4002I Watchdog [arg1] Failed to Capture Screen.
Error
FQXSPOS4003I Platform Watchdog Timer expired for [arg1]. Error
FQXSPOS4010I OS Crash Video Capture Failed.
Error
FQXSPPU0001N An Over-Temperature Condition has been detected on
[ProcessorElementName].
Error
FQXSPPW0002L [PowerSupplyElementName] has Failed.
Error
FQXSPPW0007L [PowerSupplyElementName] has a Configuration Mismatch. Error
FQXSPPW0035M Numeric sensor [NumericSensorElementName] going low (lower
critical) has asserted.
Error
FQXSPPW0047M Numeric sensor [NumericSensorElementName] going high (upper
critical) has asserted.
Error
FQXSPPW0061M Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPPW0062M Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPPW0063M Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPPW0110M Non-redundant:Insufficient Resources for
[RedundancySetElementName] has asserted.
Error
FQXSPSD0001L The [StorageVolumeElementName] has a fault.
Error
FQXSPSD0002L Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has a fault.
Error
FQXSPSD0005L Array [ComputerSystemElementName] is in critical condition. Error
FQXSPSD0006L Array [ComputerSystemElementName] has failed. Error
FQXSPSD0007L Array critical asserted on drive [arg1] in the enclosure/chassis (MTM-
S/N: [arg2]).
Error
FQXSPSD0008L Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
Error
FQXSPSE4000I Certificate Authority [arg1] has detected a [arg2] Certificate Error. Error